Hardfloor PU-2K Coating
Hardfloor PU-2K Coating

Hardfloor PU-Beschichtung

Artikel nr.: 69041045A EAN: 5708055051316 69042045A EAN: 5708055051323

Für die Renovierung von LVT-, Vinyl- und Linoleumböden

  • Langlebiger PU-Schutz
  • Verlängert die Lebensdauer des Bodens
  • Ideal für die Renovierung bestehender Böden
  • Widerstandsfähig gegen Schmutz und Flüssigkeiten
  • Nachhaltige Lösung, Renovierung statt neu
  • Reduzierter Wartungsaufwand

Farben

Farblos – Matt
Farblos – Seidenmatt

Verpackung

Zertifizierungen

Environmental Product Declaration (EPD)
Environmental Product Declaration (EPD) supports greater transparency and documented sustainability. EPDs present verified data on a product’s environmental impact throughout its entire life cycle, based on recognized standards and third-party verification.
DiBt
DIBt is a German institute that tests and issues technical approvals for building materials.The aim is to improve the working climate for floor installers whilst ensuring a safe indoor air quality for the final consumer.
Danish Indoor Climate Labelling
Danish Interior Climate Labelling is a voluntary labelling system for products and materials which can document the effect of degassing. Indoor climate labelled materials are a natural component in sustainable construction, where a good indoor air quality contributes to social sustainability.
Emission Class A+
The French labeling system is a mandatory classification of materials, such as floor treatment products, based on their VOC emissions to indoor air. A+ is the highest rating, indicating improved indoor air quality with very low emissions.
Fire test
European standard specifying how building materials react in case of fire. Bfl-s1 classifies flooring with low combustibility and very low smoke development.
EN 71-3
European standard ensuring that materials do not release toxic substances in amounts harmful to children. Particularly relevant for materials such as toys, kitchen utensils, worktops and furniture.
Anti Slip - R9
DIN 51130 is a standardised anti-slip test for flooring. It is typically used for work places and official buildings where there is a requirement that products have the anti-slip test DIN 51130 with a classification from R9 to R13.
Environmental Product Declaration (EPD)
Environmental Product Declaration (EPD) supports greater transparency and documented sustainability. EPDs present verified data on a product’s environmental impact throughout its entire life cycle, based on recognized standards and third-party verification.
DiBt
DIBt is a German institute that tests and issues technical approvals for building materials.The aim is to improve the working climate for floor installers whilst ensuring a safe indoor air quality for the final consumer.
Danish Indoor Climate Labelling
Danish Interior Climate Labelling is a voluntary labelling system for products and materials which can document the effect of degassing. Indoor climate labelled materials are a natural component in sustainable construction, where a good indoor air quality contributes to social sustainability.
Emission Class A+
The French labeling system is a mandatory classification of materials, such as floor treatment products, based on their VOC emissions to indoor air. A+ is the highest rating, indicating improved indoor air quality with very low emissions.
Fire test
European standard specifying how building materials react in case of fire. Bfl-s1 classifies flooring with low combustibility and very low smoke development.
EN 71-3
European standard ensuring that materials do not release toxic substances in amounts harmful to children. Particularly relevant for materials such as toys, kitchen utensils, worktops and furniture.
Anti Slip - R9
DIN 51130 is a standardised anti-slip test for flooring. It is typically used for work places and official buildings where there is a requirement that products have the anti-slip test DIN 51130 with a classification from R9 to R13.
Produktdetails

WOCA Hardfloor PU-2K Coating ist eine effektive Wartungslösung, die LVT-, Vinyl- und Linoleumböden vor täglichem Verschleiß schützt und die Lebensdauer des Bodens verlängert. Die langlebige und leicht zu reinigende Oberfläche reduziert die Schmutzaufnahme und den Wartungsaufwand, was sie ideal für stark frequentierte Bereiche macht.

  • Sicherheitsdatenblatt auf Anfrage erhältlich.
  • Enthält: 1,2-benzisothiazol-3(2H)-one; Reaction mass of 5-chloro-2-methyl-4-isothiazolin-3-one and 2-methyl-2H -isothiazol-3-one. Kann allergische Reaktionen hervorrufen.
VOC:
90 g/l, Grenzwerte für den VOC-Höchstgehalt (A/e (Wb)): 130 g/l.
Dichte:
1.00-1.10 g/ml.
pH-Wert:
pH 7-8
Haltbarkeit:
2 Jahre
Verarbeitungstemperatur:
+15-25°C bei ugf. 50% Luftfeuchte.
Ergiebigkeit:
8-10 m²/L
Colour product:
Farblos – Matt
Verpackungsgrößen:
4,5 L
VOC:
90 g/l, Grenzwerte für den VOC-Höchstgehalt (A/e (Wb)): 130 g/l.
Dichte:
1.00-1.10 g/ml.
pH-Wert:
pH 7-8
Haltbarkeit:
2 Jahre
Verarbeitungstemperatur:
+15-25°C bei ugf. 50% Luftfeuchte.
Ergiebigkeit:
8-10 m²/L
Colour product:
Farblos – Seidenmatt
Verpackungsgrößen:
4,5 L

Wir empfehlen einen Probeanstrich an einer unauffälligen Stelle um das Ergebnis beurteilen zu können.

  • Vor dem Nassschleifen muss der Boden gemäß den Anweisungen des Bodenherstellers von vorherigen Oberflächenbehandlungen befreit werden.
  • Den Boden mit Körnung 400 (bordeauxrotes Pad) nass schleifen unter Verwendung von WOCA Hardfloor Intensiv Cleaner im Mischverhältnis 1:10.
    Den Schleifschlamm mit WOCA Hardfloor Intensiv Cleaner im Mischverhältnis 1:40 entfernen und die Flüssigkeit sofort mit einem Nasssauger aufnehmen.
    Hinweis: Mikroplastik muss als Umweltabfall entsorgt werden.
  • WOCA Hardfloor PU Coating und Härter müssen vor Gebrauch gründlich geschüttelt/gerührt werden.
    Lassen Sie die Mischung 10 Minuten ruhen, bevor Sie sie auftragen, um den Härter zu aktivieren. Die Oberfläche muss vor dem Auftragen vollständig trocken sein.

    Hinweis: Linoleum hat eine längere Trocknungszeit als andere Materialien.

    Die vorbereitete Mischung muss innerhalb von 4 Stunden verwendet werden.

  • Trocknungszeit vor dem nächsten Anstrich (falls erforderlich): 2–3 Stunden bei normaler Raumtemperatur.
    Wir empfehlen 2 Anstriche mit Hardfloor PU Coating für optimale Stärke und Haltbarkeit.
  • Der Untergrund muss stabil, trocken und für die Renovierung geeignet sein.

    Produkte, die Sie benötigen